B6 Brake
The B6 power off, fail safe holding brake is a special NEMA23 mount version designed to mount directly on the front of the EA057A motors without adapter. It has a NEMA23 flange and much larger ½” input and output shaft. The B6 is designed to hold a load in position when power is removed from the motor and brake.
Features:
- Holding torque of 0.339 Nm
- Special NEMA23 face mount with larger ½” shaft
- 24Vdc
Specifications
BRAKE DATA |
UNITS |
B6 |
Applied Voltage |
Vdc |
24 |
Holding Torque |
Nm |
0.339 |
lb-in |
3.0 |
Current |
A |
0.18 |
Resistance |
Ohms |
132 |
Inertia |
Kg-m2 |
3.60E-06 |
oz-in-sec2 |
5.1E-04 |
Weight |
Kg |
0.5 |
Lbs |
1.1 |
Dimensional Drawings
DIMENSIONS - inches (mm)
Model |
B6 |
A (3) |
2.250 (57.15) |
B (4x) |
0.205 (5.21) |
C (2) |
16.75 (425.0) |
H (3) |
1.18 (29.97) |
L (1) |
3.031 (76.99) |
U (1) |
0.4997 (12.69) |
U2 (3) |
0.145 (3.68) |
AH (3) |
0.70 (17.78) |
AJ (3) |
2.625 (66.68) |
AK (1) |
1.500 (38.1) |
BB (3) |
0.10 (2.54) |
Notes: |
All Brake Data is at 20 degrees C |